Mechanical timers - type 601
Application
Due to their structure mechanical timers type 601 have possibility of plugging in more outer appliances than timers type 600. Just as mechanical timers type 600 they are applied in electrical appliances and systems which function duration must be limited, e.g. radiation appliances, heating systems, drying ovens, grills, electric blankets, kitchen appliances, ventilators, medical equipment, washing machines, centrifuges, sauna, tanning beds, etc.
Product information
- standard programmed times of 4, 6, 15, 30, 60, 90 and 120 min;
- optionally with hold position;
- optionally with bell signal;
- possibility of simultaneous plugging in two outer appliances;
- optionally with pre-switching;
- maximal number of contacts: 6;
Dane techniczne
Switching rate: | 16(3)A/250 V AC 10(2)A/400 V AC 13A/250 V AC+++ |
Contact distance: | 3mm |
Contact switching: | immediate |
Acceleration torque button (with hold position): |
max. 50g/cm2 |
Minimum wind up angle: | 30° (resetting in reverse direction allows for setting very short programs) |
Maximum ambient temperature: | 85° (optional 120°C) |
Suitable for fitting in appliances of protection class I and II in accordance with EN 60730 | |
Torques: | |
actuating torque to wind up at the switch shaft: | approx. 0.25Nm |
friction/slide torque: | max. 0.7Nm |
static friction torque: | max. 1.0Nm |
breaking torque at the switch shaft: | max. 1.0Nm |
torque for switching into the hold position: | approx. 0.8Nm |
Accessories
Knob and dial face (see pictures) in various designs can be supplied for additional costs.
Connection
Electrical connection via tab terminals 6.3 x 0.8 mm in accordance with EN 61210, vertical or horizontal connections are optional.
Approvals
- VDE
- UL
- CSA
Detailed list of mechanical timers type 601
Click on reference number to see the detailed description.
Reference number |
Running time | Length of a shaft [mm] (B-parameter on a product information card) |
Number of contacts |
Position of contacts |
Signal | Hold function | |
---|---|---|---|---|---|---|---|
Running time [min] |
Running time tolerance [sec] |
||||||
726-010-009 | 4 | ±36 | 20 | 6 | Horizontal | No | Yes |
726-014-000
726-014-030 |
15 | ±135 | 20 20 |
6 5 |
Horizontal Horizontal |
No No |
No Yes |
726-015-000 | 30 | ±180 | 20 | 6 | Horizontal | No | No |
726-016-000
726-016-037 726-016-052 726-016-060 726-016-061 |
60 | ±180 | 20 20 24 20 22 |
5 3 6 6 3 |
Horizontal Horizontal Vertical Horizontal Horizontal |
No No Yes No No |
No Yes No Yes Yes |
726-018-000
726-018-021 726-018-023 726-018-031 726-018-032 |
120 | ±360 | 20 38.6 20 23 23 |
4 4 6 4 4 |
Horizontal Horizontal Horizontal Vertical Vertical |
No No No No No |
No No No No No |
"0" position of a shaft and other technical data available in product information cards |
If in the chart above there is no timer that you are looking for please contact us.